LIRNGroup
Send Inquiry
Process Engineering & Industrial Fabrication — Hyderabad, India

Built on decades of field-proven engineering

From rotary kilns and cyclone separators to full process plant consulting — LIRN Group fabricates, engineers, and delivers across the complete industrial spectrum.

Send Inquiry
View our work →
25+
Years in industry
500+
Projects delivered
3
Divisions
Our divisions

Three practices, one team

Each division operates with dedicated expertise. Together they cover the full lifecycle of an industrial process plant.

Equipment Manufacturing

LIRN Fabrications

Rotary kilns, cyclone separators, bag filter houses, conveyors, trusses, and heavy industrial structures — fabricated to specification.

—Rotary Kilns & Dryers
—Cyclone Separators
—Bag Filter Houses
—Conveyors & Elevators
—Trusses & Sheds
Explore equipment →
Process Engineering

LIRN Solutions

Root cause analysis, pressure loss budgets, duct sizing, system documentation, and full plant consulting for mineral processing operations.

—Root Cause Analysis
—Pressure Loss Budgets
—Duct Sizing & Design
—System Documentation
—Bleaching Earth Consulting
View services →
Coming Soon

LIRN Clay Tech

Calcium bentonite bleaching earth — thermally activated and supplied for edible oil refineries. Processing operations launching soon.

—Calcium Bentonite
—Bleaching Earth
—Edible Oil Grade
—Custom Activation
—Direct Supply
Get notified →
Equipment we fabricate

Built to spec, built to last

View all equipment →
Case study

From backfire to stable operation — in one engagement

Our first LIRN engagement diagnosed a recurring furnace backfire and visible stack emissions at a 10 TPH calcium bentonite processing plant in Karnataka.

Client and project details anonymized. Technical findings shared for reference only.
Read the full case study
LIRN Solutions — Process Engineering

Kiln Bag Filter RCA — 10 TPH Calcium Bentonite Plant, Karnataka

85%
Fan draft recovered
74%
Energy saved
0
Backfire events after fix
Problem

Cyclic furnace backfire every 2-3 minutes. Visible dust from the stack. Two 600 mm ducts consuming 85% of ID fan draft capacity.

Fix

Enlarge ducts to 1,000-1,200 mm. Switch to DP-triggered pulse cleaning. Reduce ID fan from 47 Hz to 25-32 Hz post-fix.